Comparison of oxygenation and ventilation parameters between proseal laryngeal mask airway and endotracheal tube in patients undergoing laparoscopic surgeries: a prospective observational study

  • Authors Details :  
  • Deepak Devendran,  
  • Karthik Jain M,  
  • Vasudeva Upadhyaya K.s

Journal title : Indian Journal of Clinical Anaesthesia

Publisher : IP Innovative Publication Pvt Ltd

Online ISSN : 2394-4994

Page Number : 529-537

Journal volume : 5

Journal issue : 4

637 Views Research reports

Introduction: Use of endotracheal tube (ETT) has many limitations. There is a need for an airway device with similar safety and good side effect profile. In this prospective observational study, the oxygenation and ventilation parameters between patients who were inserted Proseal laryngeal mask airway (PLMA) or ETT for laparoscopic surgeries were compared. Materials and Methods: After ethical committee approval, informed consent was obtained from sixty patients (thirty in each group) posted for elective laparoscopic surgery. Following induction of general anaesthesia and paralysis, PLMA or ETT was inserted and pressure control mode was used for ventilation. The following parameters were measured: a. Oxygen saturation and changes in FiO2 needed to ensure a target SpO2> 95%, EtCO2 and changes in respiratory rate and inspiratory pressure needed to ensure a target EtCO2 between 35-45 mmHg. b. Insertion characteristics of airway device and gastric tube, hemodynamic responses, incidence of complications. Statistical Analysis: Chi-square test was used to analyze qualitative data. Independent t test was used to assess quantitative variables. Repeated measures ANOVA was used to compare the outcome measures over time adjusted for duration of surgery and anaesthesia. P values<0> Results: Both groups were comparable with respect to age, gender and weight. Oxygenation and ventilation parameters achieved with both ETT and PLMA were comparable and satisfactory. Haemodynamic parameters increased significantly in ETT group compared to PLMA group during airway insertion and removal. Also, postoperative sore throat was comparatively less in the PLMA group. Conclusion: Hence we conclude that PLMA may be considered as an alternative to ETT in airway management of patients undergoing laparoscopic surgeries with comparable oxygenation and ventilation parameters and improved side effect profile.

Article DOI & Crossmark Data

DOI : https://doi.org/10.18231/2394-4994.2018.0101

Article QR Code

Comparison of oxygenation and ventilation parameters between proseal laryngeal mask airway and endotracheal tube in patients undergoing laparoscopic surgeries: a prospective observational study QR Code

Article Subject Details


Article Keywords Details



Article File

Full Text PDF





More Article by Kamal Singh

Importance of using basic statistics adequately in clinical research

Justificativa e objetivo: o uso inadequado da estatística básica é o maior responsável peloerro de interpretac ̧ão dos artigos científicos. o objetivo deste artigo de revisão foi r...

The secret language of birthdays pdf

The secret language of birthdays: your complete personology guide for each day of the year by by goldschneider, gary, elffers, joost (paperback) this the secret language of birthda...

Cold cook methods: an ethnographic exploration on the mythsof methamphetamine production and policy implications

Background urban legends and myths are prevalent in drug-use environments. however, the distinction between myth and fact is not always clear. we found contradictory claims regardi...

Innovative ideas to sustain in covid-19 lockdown-a case study

The covid-19 lockdown has made many people of the middle- and lower-income class think and reinvent themselves to sustain in this crisis. it was difficult for lower- and middle-inc...